hallo.I have a simple macro to batch all processes, including routhing one.this is possible because I use thiss macro, that get off dialog messages: DIALOGS MESSAGE OFFBATCH PROCESSDIALOGS MESSAGE ON I discovered that if I use this batch process , in case powermill get a mssage like this: "Roughing parallel passes Profiling none can create unsafe paths"because of 'AreaClearance.Profile.Sequence' 'none' , but thhe warning message was hidden by the "dialog message off" into the batch process macro I use. the one above.I didn't read the message , because of dialogs message were off.The milling machine got collisions, because toolpath was really unsafe, So I ask:Is it possible to exclude this particular message? and let the batch process go until the end on all toolpaths? Is it possible to stop the macro giving me a message just in case I am in the 'AreaClearance.Profile.Sequence' 'none' option?or, maybe, if the macro will confirm or doesn't stop when appears the following message Some areas may not have been machined as completely as expected, leaving more material than the specified allowanceor best, do you know other doungerous messages that must be viewed but dialog message off cut them out? otherwise I should give up having my batch process macro without confirming with the enter key after each roughting toolpath. thanks a lot to any helper greetingsDanny