@vishubandal12,Both VC FC modules in bays 2 and 5 should be replaced before assigning the new 32Gb LIG. Do not run a redundant LIG with one 16Gb and one 32Gb module.After both modules are replaced:1. Create the new 32Gb LIG with the required FC networks and uplink sets.2. Assign it to the enclosure group.3. Run Update from group on the logical enclosure.4. Verify FC zoning, SAN paths, and boot-from-SAN access.The update affects the logical interconnect for both bays. Therefore, both FC paths could be interrupted during the change. ESXi may continue running if multipathing works correctly, but this should be treated as a potentially disruptive maintenance activity.An interim A-side/B-side LIG split for bays 2 and 5 is not supported. Host shutdown may not be required, but because the hosts boot from SAN, confirm the exact procedure with HPE Support before proceeding.

Схожие новости

#Наименование новостиТональностьИнформативностьДата публикации
1Re: Query Regarding Replacement of VC FC 16GB Module with VC FC 32GB in Synergy09.213-10-2026
2Ynt: Proliant dl380 gen10 with HPE Smart Array P816i-a SR Gen10 - Logic Drives Failure010.7613-10-2026
3Ynt: Proliant dl380 gen10 with HPE Smart Array P816i-a SR Gen10 - Logic Drives Failure012.4613-10-2026
4Re: confirmation if QLE2772 HBA is supported for direct FC connectivity with the HPE Q6Q09.2112-10-2026
5Re: Gen10 server with mr416i-p gen 10plus nvme support012.9313-10-2026
6Memory Tiering and VM Memory Reservation: What You Actually Need to Know023.7406-08-2026
7Demystifying VMware vSphere, vCenter, and ESXi: Key Components of Virtualization020.2102-08-2026
8Переход на zVirt 5.0: что меняется на каждом узле и как не сорвать обновление0709-07-2026
9StorMagic and Supermicro Team Up to Simplify High-Availability Edge Infrastructure0524-06-2026
10VMware Cloud Foundation® 9.1 徹底解説!vCenter で直感的に構築する「VPC」と「分散トランジットゲートウェイ」設定ガイド019.303-08-2026

Классификация: . Схожих патентов: 0. Схожих новостей: 10. Тональность: 0. Информативность: 8.7. Источник: community.hpe.com.